Calibration field · IEC 60060-2
Calibration software for high voltage laboratories
What instruments does it cover?
3 instrument types, supplied with the software, each with a default interval, a calculation sheet and a measurement model checked against the standard it cites:
- High-Voltage Measuring System
- Dielectric Strength (Hipot) Tester
- High-Voltage Insulation Tester
Anything not listed, you add as your own type, kept separate from the catalogue so that what the software has checked and what you have checked are never in the same list.
Which standards is the work done to?
- IEC 60060-2
- IEC 61180
- Manufacturer’s published specification
Named on the field, never invented by the software. Where a standard sets a one-sided limit, the starting plan fills it in; where an accuracy belongs to the instrument in front of the technician, the plan leaves it blank, because a plausible number from nowhere is how a wrong tolerance reaches a certificate.
What happens on the bench?
An instrument of these types opens on the general sheet: limits derived from the instrument's declared accuracy specification, never typed, with a statement of conformity under your declared decision rule. Readings are typed or taken from a connected instrument; the arithmetic runs in a deterministic engine that recomputes at issue and refuses on any mismatch. Starting plans supplied for this field: High-voltage measuring system — scale factor and linearity, Hipot tester — voltage, trip current, time and High-voltage insulation tester — each test voltage. Each is copied into your own plans and completed there.
What does the certificate say?
Each result with its uncertainty in the same unit, the master cited with its own certificate number, the method and version, the decision rule wherever a pass or fail is stated, the signatory, and page n of N. The certificate requirements guide lists every clause.
How often?
Twelve months is the convention. IEC 60060-2 also asks for performance checks between calibrations, which belong to whoever uses the system. The recall then runs itself: one email a month per customer listing everything due or overdue.
What do your customers see?
Every certificate you issue is in your customer's own portal, under your name, beside what falls due — to download and verify without phoning you. You choose which sections they see, and portal logins are never charged for.
CalibraWorks is calibration software for high voltage work in Australia: 3 instrument types to IEC 60060-2, IEC 61180 and Manufacturer’s published specification, from enquiry to certificate to invoice to recall, built to ISO/IEC 17025 with the records kept as you work.
Questions about high voltage
- What does a high voltage certificate carry?
- Each result with its measurement uncertainty in the same unit, the reference standard cited with its own certificate number, the method and version, the decision rule wherever a pass or fail is stated, the authorised signatory, and page n of N. Every item ISO/IEC 17025 §7.8.2 and §7.8.4 require, and a QR code a stranger can verify without an account.
- Our instruments are not all in this list. Can we add our own types?
- Yes, on every plan. A type you create starts on the general tolerance-band sheet, is listed separately from the supplied catalogue so the register never implies the software vouches for it, and takes your own procedure. The catalogue types are checked against the standard they cite; yours are validated by you, which is what §7.2.2 asks.
- How often should these be calibrated or inspected?
- Twelve months is the convention. IEC 60060-2 also asks for performance checks between calibrations, which belong to whoever uses the system. The interval is yours to set per instrument type and per customer; the software records it and drives the recall from it, and never prints a recommendation on a certificate unless the customer has agreed one (§7.8.4.3).
- Does choosing this field restrict what else we can do?
- No. A field shapes the defaults a laboratory starts with: its instrument types, its starting plans, and the vocabulary on empty screens. A pressure laboratory can calibrate a torque wrench the same afternoon, and a force laboratory can inspect lifting gear. Mixed deliveries go on one job, and the document follows the item.
Start free. Thirty days, everything included.
No card, and one trial per organisation. Nothing is deleted when a trial ends — the records are yours and stay readable and exportable.