Calibration field · ISO 15189:2022 §6.4–6.5
Calibration software for pathology and medical laboratories laboratories
What instruments does it cover?
9 instrument types, supplied with the software, each with a default interval, a calculation sheet and a measurement model checked against the standard it cites:
- Single-Channel Pipette
- Multichannel Pipette
- Burette (Glass or Piston)
- Volumetric Flask
- Volumetric or Graduated Pipette (Glass)
- Water Bath
- Dry Block Heater / Heat Block
- Blood Bank Refrigerator
- Plasma Freezer
Anything not listed, you add as your own type, kept separate from the catalogue so that what the software has checked and what you have checked are never in the same list.
Which standards is the work done to?
- ISO 15189:2022 §6.4–6.5
- ISO 8655-6:2022
- ISO 8655-2:2022
- ISO 4787:2021
- ISO/TR 20461:2023
- EURAMET cg-19
- EURAMET cg-20
Named on the field, never invented by the software. Where a standard sets a one-sided limit, the starting plan fills it in; where an accuracy belongs to the instrument in front of the technician, the plan leaves it blank, because a plausible number from nowhere is how a wrong tolerance reaches a certificate.
What happens on the bench?
An instrument of these types opens on the general sheet: limits derived from the instrument's declared accuracy specification, never typed, with a statement of conformity under your declared decision rule. Readings are typed or taken from a connected instrument; the arithmetic runs in a deterministic engine that recomputes at issue and refuses on any mismatch. Starting plans supplied for this field: Water bath or heat block — positions at the set point and Blood fridge or plasma freezer — display, probe and positions. Each is copied into your own plans and completed there.
What does the certificate say?
Each result with its uncertainty in the same unit, the master cited with its own certificate number, the method and version, the decision rule wherever a pass or fail is stated, the signatory, and page n of N. The certificate requirements guide lists every clause.
How often?
Twelve months is where a laboratory starts; ISO 15189 asks it to decide from use and history, and a pipette in daily use is often checked quarterly between calibrations. A blood fridge is also watched continuously by its own alarm — the calibration is of the display and the probe, not of that watching. The recall then runs itself: one email a month per customer listing everything due or overdue.
What do your customers see?
Every certificate you issue is in your customer's own portal, under your name, beside what falls due — to download and verify without phoning you. You choose which sections they see, and portal logins are never charged for.
CalibraWorks is calibration software for pathology and medical laboratories work in Australia: 9 instrument types to ISO 15189:2022 §6.4–6.5, ISO 8655-6:2022, ISO 8655-2:2022, ISO 4787:2021, ISO/TR 20461:2023, EURAMET cg-19 and EURAMET cg-20, from enquiry to certificate to invoice to recall, built to ISO/IEC 17025 with the records kept as you work.
Questions about pathology and medical laboratories
- What does a pathology and medical laboratories certificate carry?
- Each result with its measurement uncertainty in the same unit, the reference standard cited with its own certificate number, the method and version, the decision rule wherever a pass or fail is stated, the authorised signatory, and page n of N. Every item ISO/IEC 17025 §7.8.2 and §7.8.4 require, and a QR code a stranger can verify without an account.
- Our instruments are not all in this list. Can we add our own types?
- Yes, on every plan. A type you create starts on the general tolerance-band sheet, is listed separately from the supplied catalogue so the register never implies the software vouches for it, and takes your own procedure. The catalogue types are checked against the standard they cite; yours are validated by you, which is what §7.2.2 asks.
- How often should these be calibrated or inspected?
- Twelve months is where a laboratory starts; ISO 15189 asks it to decide from use and history, and a pipette in daily use is often checked quarterly between calibrations. A blood fridge is also watched continuously by its own alarm — the calibration is of the display and the probe, not of that watching. The interval is yours to set per instrument type and per customer; the software records it and drives the recall from it, and never prints a recommendation on a certificate unless the customer has agreed one (§7.8.4.3).
- Does choosing this field restrict what else we can do?
- No. A field shapes the defaults a laboratory starts with: its instrument types, its starting plans, and the vocabulary on empty screens. A pressure laboratory can calibrate a torque wrench the same afternoon, and a force laboratory can inspect lifting gear. Mixed deliveries go on one job, and the document follows the item.
Start free. Thirty days, everything included.
No card, and one trial per organisation. Nothing is deleted when a trial ends — the records are yours and stay readable and exportable.