1. Does the software block an out-of-calibration reference standard?
Why it matters. ISO/IEC 17025 §6.4.6 and ISO/IEC 17025 §6.5 make every result only as good as the master it was measured against. A warning that can be clicked past is how certificates are issued against lapsed standards — and how a laboratory ends up recalling them.
How CalibraWorks does it. Every run names its reference standards, and the database refuses a run against one that was out of calibration on the day — a hard block, not a prompt. Each master keeps its full calibration history; extending its interval takes one person to ask and another to approve; and when a master is found out of calibration, every result that depended on it is listed in one place.
2. How does calibration software handle measurement uncertainty?
Why it matters. ISO/IEC 17025 §7.6 and ISO/IEC 17025 §7.8.4 expect an uncertainty on every calibration result, and ISO/IEC 17025 §7.11.2 expects the arithmetic behind it to be validated. A budget that lives in a copied workbook is a budget nobody can prove.
How CalibraWorks does it. A GUM budget for every point — the contributions, their divisors, the combination, the Welch–Satterthwaite effective degrees of freedom and the coverage factor — printed in the result's own unit. It is computed by one deterministic engine in decimal arithmetic, never floating point: force and jacks graded to AS 2193:2005, load cells, direct-reading force, pressure gauges to DKD-R 6-1, and a tolerance-band sheet for everything else. Raw readings and engine version are stored, and issuing recomputes and refuses on any mismatch, so a certificate reproduces byte-for-byte years later. The same arithmetic runs in the free uncertainty budget calculator.
3. Does it apply a decision rule under ISO/IEC 17025 §7.8.6?
Why it matters. A pass or fail on a certificate is a statement of conformity, and ISO/IEC 17025 §7.8.6 asks how the uncertainty was taken into account — agreed with the customer under ISO/IEC 17025 §7.1.3. Simple acceptance and guard banding share the risk differently; the choice is the laboratory's.
How CalibraWorks does it. A statement of conformity cannot be issued until the laboratory has declared its rule, and the rule is printed on the certificate, so the customer reads how the uncertainty was taken into account beside every pass and fail. Decision rules and guard banding, explained.
4. Are certificates immutable, and how are amendments handled?
Why it matters. ISO/IEC 17025 §7.8.8 allows a certificate to change only by a new, identified document. A file that can be edited after issue is not a record an assessor — or your customer's auditor — can rely on.
How CalibraWorks does it. Issued certificates are stored where they cannot be overwritten, with their SHA-256 recorded. A correction reopens the work and issues the next revision of the same number with its reason; the original is kept for good. Every certificate, sticker and test tag carries a 12-character random verification code: anybody holding the instrument scans it and sees whether the document is current, amended or withdrawn — with no login, and never switched off for non-payment.
5. Who is allowed to sign a calibration certificate?
Why it matters. ISO/IEC 17025 §6.2.6 requires authorisation for each activity, and it is often the first thing an assessor tests: pick a certificate, ask who signed it, ask for their competence record for that method on that date.
How CalibraWorks does it. Issue checks the signatory's current competence record for the method in the database, not on the screen. Competence, training and authorisation are records of their own — and a laboratory of one can have its competence assessed by a named external assessor, so a sole practitioner has a route that does not depend on hiring anybody.
6. How should calibration recall reminders work?
Why it matters. Recall is where a laboratory's repeat revenue comes from, and a reminder per instrument per week trains customers to stop reading. The right cadence brings the instrument back without becoming noise.
How CalibraWorks does it. One email a month per customer, listing everything due within sixty days or overdue, with the bands counted from each instrument's own due date rather than the calendar month. After three overdue notices it stops and the instrument goes on the laboratory's call list. Send it by hand or let it run each month on its own. How recall works.
7. Can one system handle calibration and test and tag?
Why it matters. Test and tag to AS/NZS 3760:2022 is inspection, not calibration, and the two documents must never be confused. Running two systems for one customer means two registers, two schedules and two invoices.
How CalibraWorks does it. 21 fields — 15 calibration and 6 inspection, including test and tag, electrical safety equipment, lifting and height safety, hazardous area inspection, medical equipment safety testing and biological safety cabinets and fume cupboards — and 99 instrument types. A batch grid takes hundreds of items a day, and next-test-due tags print at the point of test. An inspection report is decided by the item, carries no grade or uncertainty and never an accreditation mark. One customer register, one recall, one invoice and one portal for both, with no module fee. Calibration and Test & Tag.
8. Will it scale to several sites and a growing team?
Why it matters. A laboratory that wins work adds people, then premises, then accreditation sites. Software that fits on day one and fights on day five hundred costs a migration.
How CalibraWorks does it. Each of your premises is a branch with its own jobs, reference standards and accreditation site number, while customers, instruments, recall and the quality system stay one. The database refuses a write at a branch somebody does not work at. 10 built-in roles, roles of your own from the same permissions, field technician seats at $25 a month for people who record readings on assigned work, and up to 10 read-only logins free. Multi-site includes 12 people and 3 locations, with more at $99 a location. A schedule and dispatch board books bench work and site visits, and a read-only API ($149 a month as an add-on) lets your other systems read the records.
9. Should customers have their own calibration portal?
Why it matters. The request a laboratory answers most is a copy of a certificate it has already sent — usually the night before somebody else's audit. A portal turns that into something the customer does themselves.
How CalibraWorks does it. A portal under your laboratory's name, on every plan: each customer signs in with a one-time code, sees only its own company — enforced by the database — and finds its instruments and due dates, every certificate and report, work in progress, quotes to accept and invoices to pay. You switch each section on or off, and customer logins are never charged for. The customer portal.
10. Can technicians record work offline in the field?
Why it matters. Plant rooms, basements, mine sites and switchrooms have no signal. If readings live on paper until somebody types them in, the transcription is a source of error the laboratory owns.
How CalibraWorks does it. Technicians take the work offline before they leave the signal. General and pressure sheets — test and tag, inspection and pressure readings — are recorded on the device and sent when it reconnects, and stay on it until the laboratory has read them back; anything refused is kept with the reason. The calculation and the issue run online, where every check behind a defensible certificate can run.
11. Should quotes, invoices and payments be in the same system?
Why it matters. Every time work is re-typed from one system into another, a job can go unbilled. When the certificate and the invoice are separate records, nothing connects them.
How CalibraWorks does it. Quotes your customer accepts online, then jobs, intake receipts and tax invoices drafted from the certificated items, so certificated work cannot be missed at invoicing. Card payments through your own Stripe account mark their invoice paid; bank transfer and PayID are reconciled from your statement; reminders stop when payment lands; Xero and MYOB import files are ready for your accountant. A team calibrating only for its own organisation switches the money screens out of the menu.
12. Who owns the calibration data, and can you export it?
Why it matters. ISO/IEC 17025 §8.4.2 makes keeping records the laboratory's obligation, whatever happens to a vendor. Certificates outlive subscriptions.
How CalibraWorks does it. Every record the laboratory holds exports as one archive of CSV files with a manifest — at any time, in any subscription state, including after a trial or a cancellation. When a subscription lapses the records stay readable, and verification keeps answering. Data ownership.
13. Where is calibration data hosted?
Why it matters. Customers in government, health, defence and infrastructure ask where their records are held. A good answer names every exception rather than saying “in the cloud”.
How CalibraWorks does it. The application, the database and laboratory files are in Sydney. What leaves Australia — Hostinger and Stripe — is named on the security page and in the privacy policy, which is generated from the list of sub-processors rather than written by hand. Security and residency.
14. Is the pricing published?
Why it matters. A price you cannot read until a sales call is a price you cannot compare, and a plan that withholds part of the quality system is a plan an accredited laboratory cannot use.
How CalibraWorks does it. Every price is on the pricing page: Solo $189, Laboratory $549, Multi-site $1,352 a month plus GST, Enterprise on application, with an estimator for your own register. All supported ISO/IEC 17025 workflows, certificate branding, customer portal logins and export are on every plan. The trial is 30 days with no card.
15. Should calibration software use AI?
Why it matters. Only where a person decides. A number on a certificate has to come from a method somebody can validate and reproduce; a language model is neither.
How CalibraWorks does it. No model computes a result, sets an uncertainty, decides pass or fail or issues a certificate — every number comes from the deterministic engine. AI only proposes: reading a customer's equipment list into intake, drafting a procedure's text for a second person to approve, and an optional assistant that answers questions and finds records as the signed-in person. Every proposal is accepted or rejected by a person.